Engineered for the most demanding free weights environments. Tested to withstand repeated 200 kg drop weights without degradation — protecting your subfloor, reducing noise transfer, and lasting the lifetime of your facility.
The Heavy Duty system uses a two-layer approach: the Shield acoustic underlay absorbs the initial impact wave and decouples the surface from the structural slab, while the Titan rubber tile provides the primary shock absorption and surface durability.
This combination delivers 28 dB of impact sound reduction — critical in mixed-use buildings where gym noise transfers to offices, apartments, or hotel rooms below.
Each component is specified individually — mix and match thickness options to match your project requirements.
Data shown for the standard 30mm Titan + 20mm Shield combination. All values from certified laboratory testing.
| Specification | Value | Test Standard |
|---|---|---|
| Shock Absorption | 61% | EN 14808 |
| Vertical Deformation | 5.0 mm | EN 14809 |
| Impact Sound Reduction (system) | 28 dB | NBN EN ISO 17025 — A-2021LAB-003 |
| Impact Sound Reduction (Titan only) | 21 dB | NBN EN ISO 17025 |
| Slip Resistance (dry) | PTV ≥ 36 (Class C) | EN 13036-4 |
| Fire Classification | Efl | EN 13501-1 |
| Material Composition | 100% recycled SBR rubber | — |
| Density (top layer) | 1,050 kg/m³ | — |
| Density (sub layer) | 1,000 kg/m³ | — |
| Total System Depth | 50mm (30mm Titan + 20mm Shield) | — |
| Tile Dimensions | 1000 × 1000 × 30mm | — |
| Warranty | 4 years commercial | — |
We'll compile a full specification pack — TDS, NBS clauses, acoustic data, and CAD drawings — within one working day.